Tuesday, October 18, 2016

Working Safely with your Biological Safety Cabinet

Loading...

Loading...

Sunday, January 3, 2016

Beating post-holiday blues and ensure safety in the lab!

Photo credits:
http://thebalancingact.net.au/
Urg, can you believe it? The holiday season finally came to an end. Well, technically it ended on January 4. And what does that mean to us, lab people? It means we are back in the lab. Well, I feel you, guys. It is really hard to start working again after the holidays. Perhaps, many of us are suffering from post-holiday blues, or worse post-holiday syndrome. We can't deny it ~ after the holiday break, we may feel sad or unhappy. Don't be alarmed. It is a normal phenomenon. Hmm, I know it is hard but we should accept reality, right? Look into the bright side ~ you will be again culturing microbes. For sure, they have missed you. 

So what are you waiting for? 
Photo credits:
https://img1.etsystatic.com

But wait! Before you streak your Petri dishes, check first if it is safe to work in your laboratory, especially in your biological safety cabinet. 

So here are a few questions for you to answer.

1. Is my BSC certified?
It is a brand new year, so for biosafety cabinets that have not been certified yet, better contact your service provider and ask for re-certification of your BSC. BSC certification is needed to ensure that:
- its performance meets manufacturer's specifications
- the filter is not damaged, if physically relocated
- the cabinet's airflow and containment factors are within safe limits.

2. Do I wear the necessary PPEs?
Photo credits:
https://heavydutytruckpart.files.wordpress.com
Sometimes, holiday season may cause us to forget all these laboratory protocols. Well, before you handle your specimens, make sure you are wearing necessary personal protective equipment. This is to minimize exposure to biohazards.

3. Have I allowed my BSC to purge prior to start of work?
To purge means to allow time for contaminated air to be removed from the cabinet environment. Yes, despite being unused during the holidays, the air inside your BSC should be purged. Better safe than sorry, ayt? Leave the blower on for at least 5 minutes before using the cabinet.

4. Is the alarm of my BSC functioning?
Photo credits:
http://cloud-3.steamusercontent.com/
Better check if the alarm is working or not, before you start your work. This is to ensure that your BSC is fully operational, including the alarms. Some BSCs have sophisticated alarm system, including sash alarms. Try to move the sash to an improper position. You will expect that the sash alarm will sound. Make sure the alarm is not in mute though. If the alarm still does not sound, then there's something wrong with your BSC. Consult your service engineer for assistance.

Photo credits:
http://a.files.bbci.co.uk/
5. Have I surface-decontaminated my BSC work zone?
Same with purge cycles, your BSC work zone should be decontaminated prior to start of work even if it is unused during the holiday break. Materials to be placed inside the BSC should also be surface-decontaminated. Do not forget to surface decontaminate all items within the BSC and remove from the cabinet when work is completed.

6. Am I using a Bunsen burner inside the BSC?
Oops, do not forget that a Bunsen burner should not be used inside the BSC since it can cause airflow disturbance and can endanger you. Your samples will also be at risk of cross contamination. When absolutely necessary, ON/OFF switching type, or electric burners can be used.

I bet you are ready to work after you've answered the questions above. 

So beat the post-holiday blues and ensure safety in the lab!

Happy culturing!

Sunday, December 20, 2015

Safety reminders before the holiday break!

Happy holidays!

Photo credits:
http://i.123g.us/

I can feel your excitement for the upcoming holidays! But guess what we have a lot of work to do. Who can relate with this? 

But do not worry my fellow laboratory scientists, we can continue our work after the holidays, right?
Photo credits:
http://38.media.tumblr.com/

However, remember that we are dealing with biohazards so we should not leave our laboratories as it is. We must ensure that our labs are safe to return to when we get back after the holiday break. 

So here are a few safety reminders:
1. Observe surface decontamination. Ensure that your biosafety cabinet is appropriately decontaminated before you leave. All items within BSCs, including equipment, should be surface-decontaminated and removed from the cabinet. Before you leave, guarantee that all work surfaces, the sides, back and interior of the glass shall be wiped with an appropriate disinfectant. 

Photo credits:
http://www.roth-heat.com/
2.  Do not rely solely on UV. In decontaminating your cabinet, you can use the UV light. But make sure you also use disinfectants. Remember, UV light is  not a substitute for routine surface decontamination.

3. Do not use the cabinet as a storage area. Gentle reminder guys, do not overload the cabinet with unnecessary items. Moreover, before you leave, make sure your biosafety cabinet should be free from materials. It should be empty when not in use, since residual culture media may provide an opportunity for microbial growth!

4. Only trained personnel should use the cabinet. Since it requires sufficient theoretical and practical knowledge for you to work safely with biosafety cabinets, make sure only trained personnel should use the cabinet while you are gone. Or better yet, limit the access to the lab. Good news! Some biosafety cabinets have access control provisions ~ key switch and/or password protection feature ~ to make sure only authorized personnel can use the cabinet. Check if your BSC has this feature!
Photo credits:
http://www.rhizolab.com/

 Ooops, for the BSCs that are not yet re-certified, make sure when you come back after the holidays, seek for your BSC's annual re-certification to start the year safe in working with biohazards. 

Thursday, November 19, 2015

Working safely in you biological safety cabinet Part 3

Here is Part 3 of this blog series to guide you in working safely in your BSC. 

9. Seek annual certification of your cabinet.

Photo credits:
www.facebook.com/EscoBiologicalSafetyCabinets1
This ensures cabinet airflows and containment factors are within safe limits. The cabinet should also be re-certified if it is physically relocated to ensure no filter damage has occurred. 

Evaluation of the effectiveness of cabinet containment should include tests for cabinet integrity, HEPA filter leaks, downflow velocity profile, face velocity, negative pressure/ventilation rate, air flow smoke pattern, and alarms and interlocks.

Special training, skills and equipment are required to perform these tests and it is highly recommended that they are undertaken by a qualified professional.


10. Observe surface decontamination.

Decontaminate work zone with cleaning agents after every use. Germicidal UV-lamps are not a substitute for good cleaning practices.

Materials to be placed inside the cabinet should be surface-decontaminated with 70% alcohol.
Photo credits:
media.licdn.com

All items within BSCs, including equipment, should be surface-decontaminated and removed from the cabinet when work is completed, since residual culture media may provide an opportunity for microbial growth. The work surfaces and interior walls should be wiped with a disinfectant that will kill any microorganisms that might be found inside the cabinet. At the end of the work day, the final surface decontamination should include a wipe-down of the work surface, the sides, back and interior of the glass. A solution of bleach or 70% alcohol should be used where effective for target organisms. A second wiping with sterile water is needed when a corrosive disinfectant, such as bleach, is used.

11. Allow purge cycles.
Leave the blower on (at least 5 minutes) before and after use so as to purge the work zone of any contaminants.
*Purge – to allow time for contaminated air to be removed from the cabinet environment
12. Observe correct sash opening height.

Photo credits:
www.firstaidandsafetyonline.com
Always set the sash to the work height when working in the cabinet. If the sash window is fully open or above the normal operating height, it may compromise your safety. 

Always remember, SAFETY FIRST before anything else.


Tuesday, October 20, 2015

Top 5 signs that you should service or replace your biosafety cabinet

From the previous blogs, we've tackled about what you should look for when buying a new biosafety cabinet. 
But why do you need to buy a new BSC in the first place? 
Here are the Top 5 Signs that you should service or replace your biosafety cabinet. Check this out.
Photo credits from:
https://www.facebook.com/EscoBiologicalSafetyCabinets1
  1. The stainless steel interior is showing signs of rust or pitting. Ooops, when you find this in your biosafety cabinet, it is time to replace your BSC. Rough surfaces (rusted) can harbor contaminants, and worst, hazardous contaminants. For sure, you don't want your samples to be cross-contaminated with rust and other particles. Moreover, rusted surface is hard to clean and decontaminate. So hassle and unsafe. 
  2. Any time an alarm sounds and does not self-correct. Are you aware that there is a thin line between life and death (a little bit exaggerated, right?) when it comes to a biosafety cabinet's alarm? Because an alarm tells you there is something wrong in your biosafety cabinet, and it may signify imminent danger to you and your environment. That is why we encourage you to seek certification, at least annually, to ensure that your cabinet is performing as expected.
  3. Is the BSC still supported by the manufacturer, are parts still available? This is what we call obsolete biosafety cabinets. It is time to give up your biosafety cabinet. Surely, you already got your money's worth. There are many available biosafety cabinets in the market with exciting and up-to-date features that may not be present in your biosafety cabinet. 
  4. The BSC no longer passes its annual certification. Well, we have already discussed the importance of certifications. (See blog: Why you should not buy a Non-Certified Biological Safety Cabinet?; What to look for in a biosafety cabinet? 2. Excellent Performance). And I quote, "the use of non-certified BSCs, technically, beats the purpose of using one."
  5. The BSC no longer meets current performance criteria. Well, the reason is just the same as no. 4.

Remember, a biosafety cabinet that performs well is important in ensuring that you and your environment are safe.



Sunday, October 11, 2015

What to look for in a biosafety cabinet? 3. Safety and Health Features

Well, you are about to use a biosafety cabinet. Surely you know why you will use one, don't you? Okay, here is the thing - you use a biosafety cabinet to ensure your, the product and environment's protection from biohazards. A biosafety cabinet is used to ensure biohazard containment. So when buying a biosafety cabinet, you should look for its safety and health features.

Guess what? A biosafety cabinet is expected to perform well - in terms of providing protection to you, the product and environment. But how can you check for this?
  • Know your cabinet. You should know what type of biosafety cabinet you will be buying. There are different classifications and types. Each type has different airflow patterns, airflow velocities, design and construction  and exhaust systems. Consider these parameters since not all types of biosafety cabinets can provide product protection, just saying.(See blog: The biosafety cabinets are on Viber, Parts 1, 2, 3, 4, 5, and 6).
  • Look for the cabinet's certification from international standards. The certification will definitely tell you that the cabinet is of quality since it is not that easy for a cabinet to be certified. Your biosafety cabinet is expected to perform well, or else your safety is in jeopardy. (See blog: What to look for in a biosafety cabinet? 2. Excellent Performance ).
Other cabinets usually focus on the above-mentioned, yet there other things about a biosafety cabinet you look into, such as:
  • Type of Filter. Biosafety cabinets usually are equipped with HEPA filter (with typical efficiency of at least 99.97% for contaminant particles with 0.3 micron size). However, we have another filter type - ULPA filter - and it is better in filtering particles (with typical efficiency of at least 99.999% for contaminants 0.12 microns or larger in diameter).
  • Blower plenum design. Blower plenum and side walls should be surrounded by a negative pressure to prevent contaminants from escaping outside. This is an added safety feature for advanced biosafety cabinets. (See Airstream® Class II Biological Safety Cabinet).
  • Antimicrobial coating. An antimicrobial coating will surely inhibit microbial growth, and if applied to a biosafety cabinet, it will be an added safety feature. There is this antimicrobial coating applied to biosafety cabinets of Esco - Isocide™ - which  is a silver-ion impregnated powder coat. (See Airstream® Class II Biological Safety Cabinet).
  • Airflow sensor. Airflow sensors can monitor real-time airflow for safety and alert the user if airflow is insufficient.
  • Cabinet construction. The cabinet shall be designed to eliminate sharp edges, protrusions in order to minimize the risk of personal harm to the operator. All metal edges shall be dressed and deburred.
  • Other features. It may not be that obvious but each feature of the biosafety cabinet can contribute to its safety and health feature.

See, there are alot of things to consider in assessing the biosafety cabinet's safety and health features. So when you plan to buy one, look for the above, too. Happy buying!


Resources:
Esco. 2015. Airstream® Class II Biological Safety Cabinets (S-Series). Available from: http://www.escoglobal.com/products/download/Biological-Safety-Cabinet-AC2-G3-brochure-A4-vC-LR.pdf [Accessed 12 October 2015].


IHS Engineering 360. 2015. HEPA Filters and ULPA Filters Information. [Online]. Available from: http://www.globalspec.com/learnmore/manufacturing_process_equipment/filtration_separation_products/hepa_filters_ulpa_filters. [Accessed 12 October 2015].



Thursday, October 8, 2015

What to look for in a biosafety cabinet? 2. Excellent Performance

Well, a biosafety cabinet is not an ordinary cabinet. It has a very important role in the lives of people dealing with biohazards. A biological safety cabinet (biosafety cabinet) is used to provide personnel, or both personnel and product protection from biohazardous materials. (See blog: Biosafety Cabinet: Defined).
But how can you ensure that the cabinet you are buying will perform as expected? 
It will be troublesome for you (if you are the operator of the cabinet) if it malfunctions unexpectedly, right? So here is a tip to assure the biosafety cabinet's performance - look for its certification from international standards specific for biosafety cabinets (See blog:  All about biosafety cabinet standards).
Photo credits from:
www.nsf.org

If the biosafety cabinet is certified to an international standard (NSF and EN are the most common standards in use today) then its performance is established. Take note that it is never easy to comply to a standard. It takes a lot of effort from the company to ensure that its line of biosafety cabinets comply to these international standards.

To pass a particular standard, a biosafety cabinet shall undergo a series of tests, such as:

  1. Pressure decay/ soap bubble/ tracer gas leak
  2. HEPA/ ULPA filter leak
  3. Noise level
  4. Lighting intensity
  5. Vibration
  6. Personnel, product, and cross-contamination protection
  7. Stability
  8. Downflow and Inflow velocities
    • Inflow velocity
    • Airflow smoke patterns
    • Drain spillage trough leakage
    • Motor/ blower performance
    • Electrical safety
There are a lot of tests for a biosafety cabinet to comply with, right? Wew. Well, this is to ensure that the biosafety cabinet will do its part - that is to provide containment for biohazards and protect the operator, product and environment.
See blog: Do you know the Most Certified Biosafety Cabinet in the World?
The certification ensures that all manufactured biosafety cabinets are of quality, safe and efficient.

Aside from the certification, look for exciting features of the cabinet, such as:
  • Airflow sensor to monitor real-time airflow for safety and alert the user if airflow is insufficient.
  • Microprocessor controller that can display all safety information on one screen.
  • Motorized window that conveniently moves by your fingertip.
  • Energy-efficient motor that can provide you energy savings.
  • ULPA filter that is 10x more efficient than usual HEPA filter.
  • LED lamp that lasts 4x longer and is brighter than fluorescent lamp.
  • Antimicrobial coating that inhibits microbial growth.
  • And many other features unique to a particular biosafety cabinet.
Well, you've looked for the certificate and exciting features and you've decided to buy. That is not the end of it. When a biosafety cabinet has been purchased and delivered to you, it shall be tested during installation. Downflow velocity and uniformity test and filter leak scan (both downflow and exhaust filters) shall be the minimum tests to be performed. 

Take note that it is your responsibility to ensure that the cabinet is tested after installation, in order to ensure all the safety requirements have been met.

And voila, you can finally use your very own biosafety cabinet.


Last reminder. Make you acquire recertification of your biosafety cabinet. Do not forget about it.
Photo credits from:
Esco Biological Safety Cabinets FB Page

Enjoy working in your biosafety cabinet! 


Thursday, September 17, 2015

Why you should not buy a Non-Certified Biological Safety Cabinet?

The terms biological safety cabinet, biosafety cabinet and microbiological safety cabinet should only be applied to those devices that meet the requirements of Classes of BSCs, based on their construction, airflow velocities and patterns, and their exhaust systems.

The role of BSCs is to provide protection when handling infectious agents.
BSCs are no ordinary cabinets. 
These devices should meet international standards, i.e. NSF/ANSI 49, EN 12469 (see blog All about biosafety cabinet standards). These standards provide a series of specifications that a biological safety cabinet must meet.
Photo credits from:
www.nsf.org

To acquire an international certification, a BSC must meet the expected performance required by the standard for tests for air velocity measurements, operator and product protection, cross contamination, air visualization, filter integrity, maintenance of temperature, acceptable noise and light levels during operation of the cabinet and acceptable design of filter mountings  and plenum, and other tests as required.

Raw materials used in biological safety cabinets should be of quality. Moreover, the production stage follows a standard process, with subsequent quality control checks. The performance of the BSC during production is tested and certified.  Down flow and inflow velocity profile, airflow smoke patterns, HEPA filter leak checks, potential electrical shock hazard, operator fatigue, and the overall safety, quality and efficiency of the cabinet are checked. Moreover, BSC operation needs to be verified at the time of installation.
It is crucial for an institution to use only certified BSCs.
The purpose of testing and certification is to ensure the balance of inflow and exhaust air, the distribution of air into the work surface, and the integrity of the cabinet. A BSC must also be routinely inspected and tested by a qualified personnel to verify that it is working properly. The safety of the personnel and the environment is not guaranteed when BSCs are not certified. People and environment may be at risk of exposure when using non-certified BSCs.
The use of non-certified BSCs, technically, beats the purpose of using one.

So if you decide to buy a biological safety cabinet, look for the certificate. This proves the BSC’s quality, safety and efficiency.

Source:
Centers for Disease Control and Prevention. Appendix A – Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets. USA. Centers for Disease Control and Prevention. Available from: http://www.cdc.gov/biosafety/publications/bmbl5/BMBL5_appendixA.pdf [Accessed August 13, 2015].